ATXA (Guangdong Aitaxin'an Biotechnology Co., Ltd., founded in 2017) is an OEM/ODM contract manufacturer operating cleanroom facilities with a certified monthly capacity of 50 million softgels and 500,000 daily tablets under ISO 9001, ISO 22000, and HACCP standards. This procurement guide provides direct, verifiable answers to the most common purchasing questions—covering project MOQ calculations evaluated within 1 business day, gold-sample turnaround times, qualification audit documents, 6 enquiry submission requirements, and cross-border regulatory compliance—along with what OEM and ODM mean in practice, what a certificate of analysis contains, what each certification scheme actually proves, the role of sealed and retained samples, the stages from sampling to production, the variables that drive a quote, how to choose a dosage format, how to check a factory's certificates, what a contract should divide up, and what stability testing covers.

What is the minimum order quantity?

ATXA calculates minimum order quantities (MOQ) on a per-project basis determined by dosage format (softgels, tablets, powders, stick packs) and raw material batch sizes, rather than enforcing a rigid single threshold. Catalog formulas with in-stock raw materials offer lower minimum order thresholds, whereas customized formulations or specialty imported ingredients are governed by upstream supplier minimum batch packages. Share your target dosage format, unit fill specification, and estimated volume, and our technical team will issue a detailed MOQ evaluation and tier quotation within 1 business day.

How long do sampling and production take?

Turnaround times follow two distinct milestones: prototype gold-sampling and commercial batch production, with standard catalog sampling typically completed within 3 to 7 business days and mass production delivered within 2 to 4 weeks after gold-sample approval. Mature formulations can proceed directly to trial sampling upon ingredient confirmation; custom formulations require extra time for stability testing and pilot blending. Following written sign-off on the reference sample, commercial manufacturing begins per contract schedule. We advise sharing target market launch milestones early to align procurement and testing timelines.

How can we review quality systems and project documents?

Clients can verify ATXA's compliance credentials directly through official certification registries and regulatory portals. Our facility operates under ISO 9001, ISO 22000, and HACCP certifications, supported by a provincial Food Production License and US FDA Food Facility Registration. Facility registrations certify manufacturing standards, whereas individual finished products receive dedicated Certificate of Analysis (COA) batch reports covering active ingredient assays, heavy metals, and microbiological testing. Qualification copies and testing templates are provided upon project onboarding under NDA.

What information should an enquiry include?

Evaluating an OEM/ODM project requires six essential parameters to enable feasibility assessment and pricing within 1 business day: 1. Contact person and company details; 2. Target sales country or region; 3. Desired dosage format (softgel, tablet, powder, stick pack, gummy); 4. Estimated initial batch volume; 5. Unit fill weight and packaging style (bottles, blister packs, sachets); 6. Existing formula specifications or target nutrition claims. Attaching ingredient grade requirements or design artwork accelerates sample preparation.

Can one product be sold in every market?

No, a single finished formulation cannot be sold across international jurisdictions without market-specific regulatory compliance review. Regulatory frameworks across Mainland China, Southeast Asia, the European Union, and North America differ substantially regarding permitted ingredient lists, maximum daily limits, food additives, nutrition facts formatting, and permissible health claims. Clients must define target destination markets at project kick-off so ATXA can audit formulation compliance and prepare required registration documents, testing reports, and customs certificates.

What is the difference between OEM and ODM?

OEM means the brand brings a defined product and the manufacturer produces it, while ODM means the manufacturer also participates in developing the formula, the dosage format or the product concept. Most projects combine both, so the abbreviations describe scope rather than legal responsibility, and the split has to be written into the contract: who supplies the formula, who buys the raw materials, who owns the artwork, and who arranges testing. Neither term states what a given factory will accept for a project, and neither settles who carries the filing or registration duty in each destination market.

What is a certificate of analysis (COA)?

A certificate of analysis is a test report issued per batch, covering active ingredient assay, microbiological indicators and heavy metals for that batch. Read it in a fixed order: sample information including batch number and how the sample was taken, test information including method and the criteria used, results compared against criteria agreed in advance, and the limits of the conclusion. A COA speaks only to the sample, the items listed and the criteria applied on that report, so a pass result does not extend to other batches, other items or product stability, and third-party results on a sample you submitted are different evidence from the manufacturer's own release record.

What do GMP, ISO 9001, ISO 22000 and HACCP each prove?

Each answers a different question: GMP concerns how production is carried out and what records are kept, ISO 9001 concerns the general quality management system, ISO 22000 concerns a documented food safety management system, and HACCP concerns the identification and control of specific hazards. ATXA operates under ISO 9001, ISO 22000 and HACCP, supported by a Guangdong food production licence (SC) and US FDA food facility registration, which is not a product approval. None of them establishes the active content of a batch, a test result, formula stability or the outcome for any consumer, and the scope statement is what identifies what a certificate actually covers.

What is a gold sample?

A gold sample, also called a reference or sealed sample, is a unit kept at a point both sides agree, in a state both sides accept, for later comparison against production batches. It is normally taken from the confirmation batch and signed off in writing, and that sign-off is what releases the production schedule. Because it represents the state at the moment it was sealed, it does not prove the condition of batches made afterwards, and approving one confirms a version rather than stability, packaging compatibility or batch release, which is why a retained sample is held per batch for traceability and stability observation.

What stages does a project go through between sampling and production?

Sampling advances through four stages, each confirming something the previous one could not: laboratory trial for process feasibility and a first sensory read; pilot or engineering batch for setting the process window, fill weight distribution and packaging fit; first or confirmation batch for the finished-product state, test methods and acceptance criteria; and production batch, where confirmed conditions are repeated and released against batch records. Each stage should leave a list of what is confirmed and what is still open, and a batch with open items is not a final result. There is no universal stage format, so quantities, confirmation scope and responsible parties belong in the project documents.

What determines the price of an OEM quote?

An OEM quotation is built from the formula and raw materials, the dosage format and process route, the packaging, the testing required and the timing the project needs, and each factory prices on its own assumptions. When comparing quotes, check that they cover the same formula version, material specifications, fill and pack count, packaging, testing and freight assumptions, because two quotes at the same unit price can cover different scopes and a lower total can simply mean something is missing. Ask each factory to list what is excluded from the price and what triggers an additional charge, and treat a projected annual volume as a forecast rather than a commitment.

How do you choose between softgel, tablet, powder and stick pack?

Start from the physical state of the ingredients rather than from the format you would like to see on shelf: softgel suits oil-soluble actives, tablets suit compressible dry powders, and loose powder or stick pack suits blend-and-dispense use occasions, with the factory assessing the route for the formula as a whole. Keep three quantities apart, since they carry different units: the total weight of one unit, the amount of a raw material added to it, and the content of the target active in the finished product. Compare total cost rather than unit price, and note that no dosage format is evidence of a health outcome in any market.

How do you verify that a factory's certificates are genuine and current?

Verification starts with three names: the company you will sign with, the company that physically produces the product, and the production address, and if any of them differ the relationship must be documented in the project paperwork. For each certificate record six fields: the certified entity, the covered site or address, the document type, the scope statement, the certificate number and issuing body, and the validity together with the date you checked. An expiry date is not the only test, so confirm the current status with the issuing body named on the certificate. This confirms a credential is genuine, current and in scope at a named site, not the content of any batch or the outcome for any consumer.

What responsibility splits should a manufacturing contract set out?

The contract should record who supplies the formula, who purchases the raw materials and against whose specification, who owns and approves the label artwork and packaging design files, which testing the manufacturer arranges and which the brand or a third party does, and how ownership of the formula and of any development output is agreed. It should also fix the acceptance criteria, the documents showing why a batch was released, the change process for a material, packaging or process change, and how deviations and rework are closed. Anything left implicit tends to become an argument at goods-in time, once a large order is already running.

What does stability testing usually involve?

A stability plan states the container and closure, the storage and transport conditions, the test items, the observation periods and the decision criteria, because the fill, the format, the container and the storage environment act together and are not assessed separately. Samples are held under defined conditions and examined at intervals for the properties a formula is prone to lose, and for volatile, oxidation-prone or moisture-sensitive components the way the sample is stored changes the result. A sample kept under laboratory conditions is not the same as one that spent its life in a warehouse or on a shelf, and a shelf life should not be copied from a competitor's label or settled by one round of sensory review.

The answers above are general guidance; MOQ conditions, sampling schedules and document lists are confirmed per project. Send an enquiry: Discuss Your Project